@@ -6,32 +6,50 @@ breadcrumbs:
|
|
|
---
|
|
|
{% include header.md %}
|
|
|
|
|
|
-### Using
|
|
|
-{:.no_toc}
|
|
|
-
|
|
|
-- Debian 10 Buster
|
|
|
-
|
|
|
-## Notes
|
|
|
-
|
|
|
-- Storage typically uses base-10 prefixes like speed but unlike memory.
|
|
|
-- Higher-end SSDs provide power loss protection which generally consists of an on-board capacitor used to flush the device cache in case of power loss.
|
|
|
- Typically DC-grade devices do but cheap consumer devices to not.
|
|
|
-
|
|
|
-## Guidelines
|
|
|
-- SSDs can be overprovisioned in order to improve performance by leaving unused space the SSD can use internally.
|
|
|
- Factories typically reserve some minimum size appropriate to the drive, but users can overprovision further by leaving space unallocated/unpartitioned at the end of the drive.
|
|
|
- It's typically not needed to overprovision newer SSDs.
|
|
|
-- After receiving a new drive or after transporting an existing drive, you may want to run a SMART conveyance test,
|
|
|
+## Guidelines and Miscellaneous Notes
|
|
|
+
|
|
|
+- While file/block sizes typically use base-2 prefixes, storage mediums typically use base-10 prefixes.
|
|
|
+- Partitioning formats:
|
|
|
+ - Master Boot Record (MBR):
|
|
|
+ - From DOS.
|
|
|
+ - Supports only 4 physical partitions, but one (and only one) physical partition may be used as an extended partition which contains logical partitions.
|
|
|
+ - Supports disks up to 2TB only.
|
|
|
+ - GUID Partition Table (GPT):
|
|
|
+ - Newer than MBR, part of the UEFI specification.
|
|
|
+ - Supports disks over 2TB.
|
|
|
+ - Some OSes requires EFI support in order to boot from GPT drives.
|
|
|
+- Addressing modes: Cylinder, head and sector (CHS) (old and HDD-based) and logical block addressing (LBA) (new and hardware agnostic).
|
|
|
+- After receiving a new drive or after transporting an existing drive, you should run a SMART conveyance test,
|
|
|
which is similar to a short test but targeted at this scenario.
|
|
|
See [smartmontools](../../linux-general/applications/#smartmontools).
|
|
|
+- Alignment and block sizes:
|
|
|
+ - Using a logical block size smaller than the physical one or misaligning logical and physical blocks will cause reduced performance, mainly for small writes.
|
|
|
+ - Typical options:
|
|
|
+ - 512: The original, still used by some drives.
|
|
|
+ - 4096: Aka "Advanced Format" or "AF". Newer than 512.
|
|
|
+ - Emulated 512: Actually 4096 but emulating 512 for compatibility reasons. Problematic when automatically selecting block size.
|
|
|
+ - Some enterprise SSDs let you to set the physical block size.
|
|
|
+
|
|
|
+### SSDs
|
|
|
+
|
|
|
+- Overprovisioning: SSDs can be overprovisioned by leaving unallocated/unpartitioned space at the end in order to improve wear leveling and performance, handled internally by the SSD.
|
|
|
+ They're already overprovisioned internally, meaning newer SSDs generally don't *need* to be manually overprovisioned.
|
|
|
+ Some enterprise SSDs allow the user specify how much overprovisioned it is.
|
|
|
+- DRAM cache: Mid-to-high-end SSDs typically use a volatile DRAM cache, which significantly improves performance.
|
|
|
+- Power loss protection:
|
|
|
+ Higher-end SSDs typically provide power loss protection, which generally consists of an on-board capacitor used to flush the device cache in case of power loss.
|
|
|
+ Typically DC-grade devices contain this mechanism but cheap consumer devices do not.
|
|
|
|
|
|
### RAID
|
|
|
|
|
|
-- HDDs: RAID 1 or RAID 6/7. Never RAID 5. RAID 10 for high load (especially IO).
|
|
|
-- SSDs: RAID 5 if three or more and RAID 1 of only two. RAID 10 for extreme load (especially IO).
|
|
|
+- With HDDs: Use RAID 1 if only two and RAID 6/7 if three or more. Never RAID 5, it's too risky.
|
|
|
+- With SSDs: Use RAID 1 if only two and RAID 5 if three or more.
|
|
|
+- Use RAID 10 for high/extreme load (expecially IOPS). Typically for HDDs, as SSDs are already pretty "fast".
|
|
|
- For lots of devices, create stripes of RAIDs where each raid handles redundancy internally (e.g. RAID 10 and 60).
|
|
|
- When creating HDD arrays, try to use drives from different batches.
|
|
|
If one if the batches has some kind of manufacturing fault, shipping damage etc., you don't want the entire array to die all at once.
|
|
|
+- After replacing a bad drive, the resilvering of the new drive typically puts a high load on the other drives.
|
|
|
+ It's not uncommon for other drives to fail during this process, which is why you never use RAID 5 with HDDs.
|
|
|
|
|
|
## Monitoring
|
|
|
|
|
@@ -39,9 +57,7 @@ breadcrumbs:
|
|
|
|
|
|
See [smartmontools](../../linux-general/applications/#smartmontools).
|
|
|
|
|
|
-#### Some HDD SMART Attributes
|
|
|
-
|
|
|
-These should stay near 0 and should not be rising. If they are, it may indicate the drive is about to commit seppuku.
|
|
|
+For HDDs, the attributes below should stay near 0 and should not be rising. If they are, it may indicate the drive is about to commit seppuku.
|
|
|
|
|
|
- 005: Reallocated Sectors Count
|
|
|
- 187: Reported Uncorrectable Errors
|