Selaa lähdekoodia

Update proxmox-ve.md

Håvard O. Nordstrand 4 vuotta sitten
vanhempi
commit
d0760b6004
1 muutettua tiedostoa jossa 9 lisäystä ja 7 poistoa
  1. 9 7
      config/server/proxmox-ve.md

+ 9 - 7
config/server/proxmox-ve.md

@@ -41,20 +41,22 @@ Follow the instructions for [Debian server basic setup](../debian/#initial-setup
 1. Don't install any of the firmware packages, it will remove the PVE firmware packages.
 1. Don't install any of the firmware packages, it will remove the PVE firmware packages.
 1. Update network config and hostname:
 1. Update network config and hostname:
     1. Do NOT manually modify the configs for network, DNS, NTP, firewall, etc. as specified in the Debian guide.
     1. Do NOT manually modify the configs for network, DNS, NTP, firewall, etc. as specified in the Debian guide.
-    1. Install `ifupdown2`.
+    1. (Optional) Install `ifupdown2` to enable live network reloading. This does not work if using OVS interfaces.
     1. Update network config: Use the web GUI.
     1. Update network config: Use the web GUI.
-    1. (Optional) Update hostname: See the Debian guide.
-    1. Update `/etc/hosts`: The short and FQDN hostnames must resolve to the IPv4 and IPv6 management address.
+    1. (Optional) Update hostname: See the Debian guide. Note that the short and FQDN hostnames must resolve to the IPv4 and IPv6 management address to avoid breaking the GUI.
 1. Update MOTD:
 1. Update MOTD:
     1. Disable the special PVE banner: `systemctl disable --now pvebanner.service`
     1. Disable the special PVE banner: `systemctl disable --now pvebanner.service`
     1. Clear or update `/etc/issue` and `/etc/motd`.
     1. Clear or update `/etc/issue` and `/etc/motd`.
     1. (Optional) Set up dynamic MOTD: See the Debian guide.
     1. (Optional) Set up dynamic MOTD: See the Debian guide.
 1. Setup firewall:
 1. Setup firewall:
     1. Open an SSH session, as this will prevent full lock-out.
     1. Open an SSH session, as this will prevent full lock-out.
-    1. Enable the cluster/datacenter firewall.
-    1. Disable NDP. This is because of a vulnerability in Proxmox where it autoconfigures itself on all bridges.
-    1. Add incoming rules on the management network for NDP (ICMPv6), ping (macro), SSH (macro) and the web GUI (TCP port 8006).
-    1. Enable the host/node firewall.
+    1. Go to the datacenter firewall page.
+    1. Enable the datacenter firewall.
+    1. Add incoming rules on the management network for NDP (ipv6-icmp), ping (macro ping), SSH (tcp 22) and the web GUI (tcp 8006).
+    1. Go to the host firewall page.
+    1. Enable the host firewall (TODO disable and re-enable to make sure).
+    1. Disable NDP on the nodes. (This is because of a vulnerability in Proxmox where it autoconfigures itself on all bridges.)
+    1. Enable TCP flags filter to block illegal TCP flag combinations.
     1. Make sure ping, SSH and the web GUI is working both for IPv4 and IPv6.
     1. Make sure ping, SSH and the web GUI is working both for IPv4 and IPv6.
 1. Set up storage:
 1. Set up storage:
     1. Create a ZFS pool or something.
     1. Create a ZFS pool or something.