@@ -316,18 +316,20 @@ Check the host system logs. It may for instance be due to hardware changes or st
|
|
|
- UDP 111: rpcbind (optional).
|
|
|
- UDP 5404-5405: Corosync (internal).
|
|
|
|
|
|
-## Ceph
|
|
|
+## Storage
|
|
|
+
|
|
|
+### Ceph
|
|
|
|
|
|
See [Storage: Ceph](/config/linux-server/storage/#ceph) for general notes.
|
|
|
The notes below are PVE-specific.
|
|
|
|
|
|
-### Notes
|
|
|
+#### Notes
|
|
|
|
|
|
- It's recommended to use a high-bandwidth SAN/management network within the cluster for Ceph traffic.
|
|
|
It may be the same as used for out-of-band PVE cluster management traffic.
|
|
|
- When used with PVE, the configuration is stored in the cluster-synchronized PVE config dir.
|
|
|
|
|
|
-### Setup
|
|
|
+#### Setup
|
|
|
|
|
|
1. Setup a shared network.
|
|
|
- It should be high-bandwidth and isolated.
|
|
@@ -347,4 +349,12 @@ The notes below are PVE-specific.
|
|
|
- Use at least size 3 and min. size 2 in production.
|
|
|
- "Add storage" adds the pool to PVE for disk image and container content.
|
|
|
|
|
|
+### Troubleshooting
|
|
|
+
|
|
|
+**"Cannot remove image, a guest with VMID '100' exists!" when trying to remove unused VM disk**:
|
|
|
+
|
|
|
+- Make sure it's not mounted to the VM.
|
|
|
+- Make sure it's not listed as an "unused disk" for the VM.
|
|
|
+- Run `qm rescan --vmid <vmid>` and check the steps above.
|
|
|
+
|
|
|
{% include footer.md %}
|