@@ -119,6 +119,14 @@ The Prometheus will create a server that listens on `prometheus_port`. The Prome
|
|
|
</configuration>
|
|
|
```
|
|
|
|
|
|
+If the machine accessing the OhmGraphite metrics is not the same machine hosting the metrics, one may have to enable the port through the windows firewall.
|
|
|
+
|
|
|
+Here's one example of enabling it in powershell, though note that there are further ways to configure the firewall for additional tightening of access (ie: only allow certain IPs to connect).
|
|
|
+
|
|
|
+```powershell
|
|
|
+New-NetFirewallRule -DisplayName "Allow port 4445 for OhmGraphite" -Direction Inbound -LocalPort 4445 -Protocol TCP -Action Allow
|
|
|
+```
|
|
|
+
|
|
|
### TimescaleDB Configuration
|
|
|
|
|
|
One can configure OhmGraphite to send to Timescale with the following (configuration values will differ depending on your environment):
|
|
@@ -192,3 +200,25 @@ Currenlty the schema and the columns are not configurable.
|
|
|
- Stop OhmGraphite service `.\OhmGraphite.exe stop`
|
|
|
- Run uninstall command `.\OhmGraphite.exe uninstall`
|
|
|
- Remove files
|
|
|
+
|
|
|
+### Debugging Tips
|
|
|
+
|
|
|
+Something wrong? Try these steps
|
|
|
+
|
|
|
+- Enter the directory where OhmGraphite is installed
|
|
|
+- Examine `OhmGraphite.log`, do you see any lines with an "ERROR"? Fix the error.
|
|
|
+- If not, enable more verbose logging in `NLog.config`. Change the following line
|
|
|
+
|
|
|
+```xml
|
|
|
+ <logger name="*" minlevel="Info" writeTo="file" />
|
|
|
+```
|
|
|
+
|
|
|
+to
|
|
|
+
|
|
|
+```xml
|
|
|
+ <logger name="*" minlevel="Debug" writeTo="file" />
|
|
|
+```
|
|
|
+
|
|
|
+- Restart OhmGraphite for the logging changes to take effect
|
|
|
+- At the bottom of `OhmGraphite.log` `DEBUG` statements should be present informing one of all the hardware sensors detected and whenever metrics are pushed somewhere.
|
|
|
+- Stumped? Open an issue with relevant parts of the log included.
|